Well Flow Metrics

Field Reference & Calculation

HomeLSD LocatorTroubleshooting GuideUnit ConverterNA Well & Land LocatorWell Summary & LiftWell DesignESP Pump DepthTubing SizeFlow LossesPower ConsumptionPCP AlternativeRod Pump ComparisonClearance & FlexPMM vs Induction MotorSurface EquipmentHPS Horizontal PumpingDisclaimer & Terms

v1.0 — Petroleum Engineering

HPS Horizontal Pumping

HPS — Horizontal Pumping

Skid-mounted horizontal pumping system (HPS / HHPS) sized against a vertical ESP — metric (m³/day, m, kPa)

Duty Point & Fluid

An HPS draws suction from a flooded surface source instead of a wellbore, so intake pressure and fluid temperature set the NPSH margin available at the pump — it is the check a downhole pump does not have.

Horizontal Pumping Unit

Selected Unit Specification

ManufacturerLevare
Housing / series538 series (136.7 mm OD)
BEP (rated flow)572 m³/day (3,600 bpd)
BEP window — up/down-thrust limits372 – 658 m³/day
Head per stage16 m
Stage limit150 stages · 2,400 m max head
Max discharge pressure23,544 kPa (3,415 psi) at sg 1.00
Thrust chamber rating98 kN
NPSH required4.5 m
Pump / motor efficiency64% / 95%

Electrical & Cost Basis

Vertical ESP Comparison

The comparison runs the same pump section and duty downhole, with cable to setting depth and rig workover in the operating cost — that is where the horizontal unit's saving comes from.

HPS Results

Enter a flow rate and the required differential head to size a horizontal pumping unit.

Where a Horizontal Unit Fits

• Water-flood and produced-water injection, where the duty is pressure rather than lift.

• Pipeline boosting, tank transfer and fluid disposal on a pad or plant with flooded suction.

• Anywhere the well cannot take a downhole pump, or a workover rig is the bottleneck.

• Skid space, NPSH available and discharge pressure rating become the limits instead of casing clearance.

Field reference only — verify before use.
HomeLSDTroubleshootConvert

Field reference only — verify before use

PetroCalc is provided for general informational, educational, and field reference purposes only. The calculations and information provided are not intended to replace manufacturer specifications or professional advice — verify all inputs, calculations, results, equipment specifications, and operating conditions before relying on them. No guarantee is made as to accuracy or suitability, and the developer is not responsible for equipment damage, production loss, injury, or other losses resulting from reliance on this application.

Read the full disclaimer & terms