Well Summary & Lift Recommendation
All current well parameters in one view, with a graph-style ESP / PCP / Rod Pump recommendation
No shared well data yet — values entered or calculated in other modules will appear here.
Design Criteria — Current Well
Well Geometry
Pressures
Fluid Properties
Tubing
Calculated Results
Additional Lift-Selection Parameters
Flow rate, viscosity, depth and TDH are read automatically from the Current Well above.
Suitability by Criterion
- ESP
- PCP
- Rod Pump
Overall Suitability Score
Recommendation
Recommended Artificial Lift
Rod Pump
Overall Score
73/100
Key Driver
Flow
Based on flow — m³/day, viscosity — mPa·s, lift depth — m, GOR 100 m³/m³, sand 0.5%.
All Methods
Criterion Breakdown
Deviation Survey (Minimum Curvature)
Max MD
2,400m
Total TVD
1,968m
Horizontal Displacement
1,160m
Max Dogleg Severity
1.70°/30m
Survey Stations
| MD (m) | Inc (°) | Azimuth (°) | |
|---|---|---|---|
| MD | TVD | N | E | Closure | DLS |
|---|---|---|---|---|---|
| 0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.00 |
| 300 | 300.0 | 0.0 | 0.0 | 0.0 | 0.00 |
| 600 | 597.8 | 22.1 | 22.1 | 31.3 | 1.20 |
| 900 | 878.8 | 94.5 | 94.5 | 133.6 | 1.60 |
| 1,200 | 1119.1 | 220.2 | 220.2 | 311.4 | 1.70 |
| 1,800 | 1543.3 | 520.2 | 520.2 | 735.6 | 0.00 |
| 2,400 | 1967.6 | 820.2 | 820.2 | 1159.9 | 0.00 |
Trajectory (Vertical Section)
Inclination & Azimuth vs MD
Dogleg Severity vs MD